Product Overview

The ECUMaster Lambda to CAN is a compact wideband controller for the Bosch LSU 4.9 oxygen sensor. It runs the sensor heater and measurement with a dedicated Bosch integrated circuit and an automotive-grade microcontroller, then sends lambda and AFR over CAN bus and on a programmable 0-5 V analog output. It is a good fit for ECUs, dashes and loggers that accept CAN data, and for adding extra wideband channels, since several controllers can share one CAN bus.

Selectable CAN profiles let the controller match message formats used by other ECUs, and a heater enable voltage threshold keeps the sensor from heating before the engine is running.

Specifications

  • Sensor: Bosch LSU 4.9
  • Supply voltage: 9-16 V
  • Current draw: up to 3 A during sensor warm-up, about 1 A nominal
  • Measured lambda range: 0.5-8.0
  • Analog output: programmable 0-5 V (revision 2 units have one analog output; revision 1 units have two)
  • Communication and setup: CAN 2.0A/B at 1 Mbps (default), 500, 250 or 125 kbps; no internal termination
  • Enclosure: IP67 with the sensor connected
  • Operating temperature: -40 to 85 °C
  • Connector: Deutsch DTM06
  • Dimensions: 25.5 x 25 x 104 mm; weight 120 g
  • Configuration: ECUMaster Light Client software

What you need

  • A USB to CAN interface for configuration (ECUMaster USBtoCAN, PEAK or Kvaser)

Lambda to CAN user manual (ECUMaster)

Frequently asked questions

Can I run more than one controller?

Yes. Multiple Lambda to CAN units can operate on the same CAN bus.

Where should the sensor be mounted?

ECUMaster recommends placing it after the turbocharger and before any catalytic converter, at least 10 degrees above horizontal with the connector facing up, where the exhaust temperature stays under 500 °C.

How is it configured?

Through ECUMaster Light Client over CAN bus, using a compatible USB to CAN interface.

Racing Tech in Grand Rapids, MI sells and supports ECUMaster systems, offers calibration and data engineering services and ships worldwide. Questions? Email info@racing-tech.net.